New & Used
Swiss Army Knives

New & Used
Leatherman Tools
Goldenseal Construction Estimating Software |
ASSEMBLY
NAME-- IN GOLDENSEAL ESTIMATING SOFTWARE |
bath vents
|
CONSTRUCTION
CATEGORY |
SUBCATEGORY |
HVAC (Heating, Ventilating,
Air Conditioning) |
HVAC- Venting |
CONSTRUCTION
ITEM DESCRIPTION |
HVAC estimating unit cost for installation of
ductwork for a typical bathroom vent fan. This price is per foot,
and works best for long runs of ducting (e.g. for bathrooms not
attached to an exterior wall).
|
UNIT
SIZE |
One lineal foot.
|
LABOR
COSTS |
We figure a worker can install about 14 feet of
vent ducting per hour.
|
MATERIAL
COSTS |
Half of a 2-foot section of 3" metal vent,
plus one ell for every 3 feet of run.
|
HARD
CONSTRUCTION COSTS, TYPICAL |
$5.01 per lineal foot of bathroom ductwork
|
SUGGESTED
QUANTITY |
No suggested length. Enter the length of duct
work required.
|
SOURCE
OF CONSTRUCTION PRICING |
Based on crew timing and/or job costing data from
several vent installations done by Turtle Creek Construction.
|
PLACES INCLUDED |
Architect Starter File, Construction
Starter File, Developer Starter File
|
Click here for more about Goldenseal construction estimating software.